德国Elementar快速氧分析仪rapid OXY cube

发布:2016-10-04 12:56 | 来源:未知 | 浏览:

rapid OXY cube

  • 唯一一台零空白的氧分析仪
  • 专利的反吹技术确保可靠的测试结果
  • 检测范围:O: 0-6mg
    样品重量:0.2mg-300mg
  • 两仓高温裂解反应炉,精度更高、寿命更长
  • 高通量的液体样品进样装置可选
  • 简单易用,智能化自动诊断
  • 校正曲线经年稳定-无需特殊标准品

Get OXYted about oxygen analysis

The rapid OXY cube is a newly developed analyzer for highly precise and matrix-independent oxygen concentration measurement. Oxygen analysis using pyrolytic conversion poses high demands to instrument technology. To guarantee a highly precise and matrix-independent result, pyrolysis temperatures up to 1450 °C are necessary.

These extreme analysis conditions can only be fulfilled by rapid OXY cube, which achieves full conversion of sample oxygen to carbon monoxide. Even persistent organic as well as most inorganic substances are digested under these conditions and are detected matrix-independently. In addition, the novel backflush technology guarantees blank-free measurements also of the most difficult samples.

Highest temperature for highest precision

Our improvements in instrument technology lead to oxygen concentration analyses with unprecedented precision (standard deviation <0.1 % absolute) and convenience. The large dynamic measurement range allows sample weights of below 1 mg as well as up to 300 mg. The rapid OXY cube also stands for unmatched user-friendliness: It is optimized for unattended overnight operation and the pyrolysis reactor can be used for several thousands of samples.

Specifications

Low instrument background
Due to the novel reactor design with fully separated gas flows a very low background signal has been achieved.

Purge&trap chromatography
Separation of carbon monoxide on a specific column for perfect separation without peak overlap and automatic optimization of the analysis time.

Backflush technology
Specifically equipped with novel backflush technology to guarantee full nitrogen-carbon monoxide separation for highly accurate analysis of oxygen.

Range of element concentrations
from ppm to 100% or 6 mg O absolute

Multipoint calibration
stable over months and matrix independent

Clean, safe, fast
The analysis only takes a few minutes, no aggressive or toxic chemicals are used, Helium carrier gas

Few installation requirements
48 x 55 cm benchtop space, 1 power supply and helium gas supply are sufficient for maintenance free long time operation

Automatic analysis run
with integrated sample feeder for 120 samples, PC control and evaluation through Windows

Instrument control
with a standard PC for perfect results also for unknown or heavily variable sample matrices; 21 CFR Part 11 Option. Possibility for remote service due to full digitalization of the instrument electronics.