德国Elementar革新性杜马斯燃烧定氮仪rapid N excee

发布:2016-10-04 12:44 | 来源:未知 | 浏览:

rapid N exceed

  • 最低的单个样品检测成本-独特的 EAS Regainer 技术
  • CO2作为载气,较He气价格便宜
  • 最高的工作效率-一根还原管可耐受2000个样品
  • 杰出的可重复性-符合ISO16624标准
  • 独特的二级燃烧,确保高精度的检测数据
  • 专利的球阀技术-无空白

Time for a change in protein analysis

50 years ago the rapid N saw the light of day for the first time!

Based on these experiences the rapid N exceed is the most economic and innovative nitrogen/protein analyzer according to Dumas. In day-to-day business it performs routine analyses of food or feed up to 1 g sample weight in your laboratory. The rapid N exceed represents the fast, safe and environmentally friendly alternative to the classical Kjeldahl method.

As the most innovative enterprise in the field of elemental analysis, Elementar takes this traditional analytical technology to a new level. This is made possible by a completely new method of reduction of nitric oxides and absorption of excess oxygen in the analysis gas. Due to a defined interaction of reduction and oxidation (patent applied for) used reduction agent will be automatically generated during operation. Thus, a reduction reactor (reductor) can be used for several thousand samples without change or maintenance.

At the same time, Elementar relies on proven technology for the newly developed rapid N exceed:

  • CO2 as carrier gas saves the finite resource helium and guarantees stable prices and constant availability.
  • The fastest protein analysis with analysis times of less than four minutes and highest sample throughput in this instrument class.
  • The post-combustion guarantees exact results, independent of any sample matrix.
  • The rapid N exceed never takes a break: it operates 24/7 – 365 days a year.

Specifications

High temperature combustion
Dumas combustion method for N-Protein acc. to AOAC, DIN/ISO, EN and many international standards

Large weighing range
Up to 1 g sample weight (1g organic matter)

Concentration range
from ppm to 100% or 500 mg N abs.

Clean, safe, fast
The analysis only takes a few minutes, no aggressive or toxic chemicals are used, CO2 as intelligent carrier gas

Easy installation requirements
48 x 55 cm benchtop space, 1 power supply (230, 110, 100 V), and two gases are sufficient for maintenance free long time operation

Multipoint calibration
stable over months and matrix independent

Instrument control
with a standard PC for perfect results also for unknown or heavily variable sample matrices, 21 CFR Part 11 functionality available. Possibility for remote service due to full digitalization of the instrument electronics